Oct 15, 2020
The series of AquaRO², AquaRO²DI, and EDI² is based on reverse osmosis (RO) units to produce deionized water. The EDI² series further processes the osmosis water by using an EDI cell to get Type II water. All systems provide you with reliable and compact systems at low operating costs. The advantage of both series is the flexibility in terms of configuration.
A production rate of 8 to 40 L/h in three different degrees of pure water (10 µS/cm to 0.2 µS/cm) is available. Optionally the systems can be equipped with a dispenser. The customer can select a 35 L,70 L, or individual tank size.
- RESISTIVITY/CONDUCTIVITY
PRODUCTION RATE
-TOTAL ORGANIC CARBON (TOC)
Model | AquaRO² | AquaRO²DI | AquaRO² 8 P10 | P10 DI | EDI² | |
1 | Pure water quality | < 10 µS/cm | < 2 µS/cm; Type II | < 10 µS/cm | < 2 µS/cm | < 0.2 µS/cm; Type II |
2 | Resistivity | 0.1 MegaOhm/cm | > 0.5 MegaOhm/cm | > 0.1 MegaOhm/cm | > 0.5 Megaohm/cm | > 5 MegaOhm/cm |
3 | Total organic carbon (TOC) | 50 ppb | < 40 ppb | < 40 ppb | < 20 ppb |
4 | Production rate | 8 L/h to 40 L/h | 8 L/h to 20 L/h | 8 L/h | 10 L/h to 40 L/h |
5 | Bacteria | 50 cfu/mL | < 50 cfu/m | < 50 cfu/mL | < 10 cfu/mL |
6 | DNAse | 5 pg/mL* | nil | nil | nil |
Model | AquaRO² | EDI² | |
1 | type of feed water | potable water / tap water | potable water / tap water |
2 | feed water conductivity | < 1400 µS/cm | < 1400 µS/cm |
3 | inlet pressure | 1.5 to 6 bar | < 5 bar |
4 | free chlorine | < 0.1 mg/L | < 0.02 mg/L |
5 | Silt Density Index (SDI) | < 3 | < 3 |
6 | pH | 3 to 9 | 3 to 9 |
7 | temperature | 5 to 25 °C | 5 to 25 °C |
8 | iron / manganese | n. a. / n. a. | < 0.01 mg/L / < 0.01 mg/L |
9 | sulfate | n. a. | < 2 mg/mL |